No records inside the last 1 days, so the
charts below are empty. This station holds 7,800 record(s)
in total — try a wider window.
Latest reading
2026-11-26 13:30 station time · 4 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
2,134cusecs
no 3 h reference
Period0 record(s) · 2021-11-01
Water level3.37 mrange 2.72–5.93
Discharge60.4 m³/srange 33.0–70.4
Flow velocity0.31 m/srange 0.30–0.33
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 35.0 dBM
Battery13.5 Vwithin range
Device temperature22.0 °Cinside the gauge enclosure
Sensor tilt51.0 °X 3.00° · Y -5.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-26 13:30
Sensor alignment
Tilt angle51.0 °
X tilt3.00 °
Y tilt-5.00 °
Telemetry & power
Level SNR35.0 dBm
Average SNR17.3 dBm
Quality of service0.00
Device temperature22.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-26 13:30
3.37
2.72
5.93
60.4
0.31
0.00
35.0
0.00
13.5
2,134
2026-11-26 13:25
2.63
1.60
5.61
13.1
0.30
0.00
33.0
0.00
13.5
461
2026-11-26 13:20
2.74
2.73
2.75
65.4
0.31
0.00
0.00
3.00
13.5
2,310
2026-11-26 13:15
5.75
1.57
18.9
28.3
0.32
0.00
33.0
2.00
13.5
999
2026-11-26 13:10
2.74
2.73
2.75
61.9
0.29
0.00
34.0
0.00
13.5
2,185
2026-11-26 13:05
2.75
2.73
2.77
57.8
0.27
0.00
37.0
0.00
13.5
2,039
2026-11-26 13:00
9.23
2.76
18.9
40.3
0.51
0.00
0.00
3.00
13.5
1,422
2026-11-26 12:55
2.77
2.76
2.77
69.2
0.32
0.00
31.0
0.00
13.5
2,444
2026-11-26 12:50
5.76
1.57
18.9
41.7
0.32
0.00
34.0
0.00
13.5
1,472
2026-11-26 12:45
6.01
2.77
18.9
57.1
0.32
0.00
0.00
0.00
13.5
2,018
2026-11-26 12:40
3.14
1.54
5.87
43.2
0.33
0.00
34.0
0.00
13.5
1,526
2026-11-26 12:35
2.77
2.76
2.78
75.2
0.34
0.00
32.0
0.00
13.5
2,654
2026-11-26 12:30
6.00
2.75
18.9
58.5
0.33
0.00
35.0
2.00
13.5
2,067
2026-11-26 12:25
2.77
2.75
2.79
66.5
0.30
0.00
33.0
0.00
13.5
2,348
2026-11-26 12:20
7.60
1.53
18.9
0.00
0.33
0.00
0.00
3.00
13.5
0.00
2026-11-26 12:15
10.5
2.79
18.9
15.3
0.33
0.00
30.0
0.00
13.5
542
2026-11-26 12:10
4.35
1.51
5.83
13.8
0.33
0.00
32.0
0.00
13.5
487
2026-11-26 12:05
2.80
2.79
2.81
121
0.53
0.00
33.0
3.00
13.5
4,287
2026-11-26 12:00
2.78
2.77
2.79
64.8
0.29
0.00
33.0
3.00
13.5
2,287
2026-11-26 11:55
2.53
1.50
2.81
73.0
0.39
0.00
37.0
1.00
13.5
2,578
2026-11-26 11:50
2.81
2.79
2.81
75.4
0.34
0.00
32.0
0.00
13.5
2,663
2026-11-26 11:45
2.07
1.38
2.80
29.1
0.31
0.00
35.0
0.00
13.5
1,026
2026-11-26 11:40
2.80
2.80
2.81
76.8
0.34
0.00
0.00
3.00
13.5
2,714
2026-11-26 11:35
2.79
2.78
2.80
68.0
0.30
0.00
37.0
0.00
13.5
2,401
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2021-11-01 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery13.5 V
Last ingest check1 min agopoller runs every 10 minutes