No records inside the last 1 days, so the
charts below are empty. This station holds 7,512 record(s)
in total — try a wider window.
Latest reading
2026-11-25 14:50 station time · 12 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
1,406cusecs
no 3 h reference
Period0 record(s) · 2022-02-17
Water level3.63 mrange 1.32–5.55
Discharge39.8 m³/srange 0.00–102
Flow velocity0.39 m/srange 0.36–0.42
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 30.0 dBM
Battery13.4 Vwithin range
Device temperature24.0 °Cinside the gauge enclosure
Sensor tilt51.0 °X 4.00° · Y -6.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-25 14:50
Sensor alignment
Tilt angle51.0 °
X tilt4.00 °
Y tilt-6.00 °
Telemetry & power
Level SNR30.0 dBm
Average SNR19.5 dBm
Quality of service0.00
Device temperature24.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-25 14:50
3.63
1.32
5.55
39.8
0.39
0.00
30.0
0.00
13.4
1,406
2026-11-25 14:45
2.91
2.90
2.92
96.8
0.41
0.00
35.0
0.00
13.4
3,418
2026-11-25 14:40
3.38
2.87
5.37
55.0
0.32
0.00
34.0
0.00
13.4
1,941
2026-11-25 14:35
6.64
2.88
18.9
54.4
0.37
0.00
34.0
0.00
13.4
1,920
2026-11-25 14:30
9.58
1.33
18.9
19.5
0.38
0.00
29.0
0.00
13.4
689
2026-11-25 14:25
6.11
2.88
18.9
70.2
0.37
0.00
34.0
0.00
13.4
2,479
2026-11-25 14:20
9.55
1.38
18.9
18.3
0.37
0.00
31.0
0.00
13.4
647
2026-11-25 14:15
7.20
2.90
18.9
35.6
0.37
0.00
0.00
0.00
13.4
1,256
2026-11-25 14:10
2.88
2.87
2.89
96.4
0.41
0.00
33.0
0.00
13.4
3,404
2026-11-25 14:05
2.88
2.88
2.88
82.7
0.35
0.00
34.0
0.00
13.4
2,921
2026-11-25 14:00
2.87
2.86
2.89
54.1
0.23
0.00
32.0
0.00
13.4
1,912
2026-11-25 13:55
13.0
2.86
18.9
18.5
0.37
0.00
36.0
0.00
13.4
652
2026-11-25 13:50
12.2
1.37
18.9
18.0
0.37
0.00
0.00
0.00
13.4
635
2026-11-25 13:45
15.7
2.88
18.9
17.5
0.37
0.00
34.0
0.00
13.4
619
2026-11-25 13:40
6.10
2.88
18.9
71.5
0.37
0.00
0.00
0.00
13.4
2,524
2026-11-25 13:35
3.97
2.86
5.63
57.3
1.76
0.00
35.0
0.00
13.4
2,025
2026-11-25 13:30
9.31
2.89
18.9
56.9
0.39
0.00
0.00
0.00
13.4
2,009
2026-11-25 13:25
13.1
2.88
18.9
17.8
0.37
0.00
30.0
0.00
13.4
627
2026-11-25 13:20
7.14
2.89
18.9
36.8
0.36
0.00
32.0
0.00
13.4
1,301
2026-11-25 13:15
9.86
2.88
18.9
34.7
0.37
0.00
32.0
0.00
13.4
1,225
2026-11-25 13:10
2.58
1.36
2.89
66.0
0.35
0.00
33.0
0.00
13.4
2,333
2026-11-25 13:05
6.58
2.86
18.9
55.4
0.39
0.00
33.0
3.00
13.4
1,956
2026-11-25 13:00
2.58
1.37
2.89
76.1
0.35
0.00
32.0
0.00
13.4
2,686
2026-11-25 12:55
7.20
2.87
18.9
43.6
0.37
0.00
33.0
2.00
13.4
1,538
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2022-02-17 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery13.4 V
Last ingest check8s agopoller runs every 10 minutes