No records inside the last 1 days, so the
charts below are empty. This station holds 6,650 record(s)
in total — try a wider window.
Latest reading
2026-11-23 00:35 station time · 10 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
3,291cusecs
no 3 h reference
Period0 record(s) · 2022-11-20
Water level6.67 mrange 3.25–18.9
Discharge93.2 m³/srange 0.00–170
Flow velocity0.51 m/srange 0.48–0.56
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 30.0 dBM
Battery12.8 Vwithin range
Device temperature11.0 °Cinside the gauge enclosure
Sensor tilt51.0 °X 3.00° · Y -6.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-23 00:35
Sensor alignment
Tilt angle51.0 °
X tilt3.00 °
Y tilt-6.00 °
Telemetry & power
Level SNR30.0 dBm
Average SNR19.4 dBm
Quality of service0.00
Device temperature11.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-23 00:35
6.67
3.25
18.9
93.2
0.51
0.00
30.0
0.00
12.8
3,291
2026-11-23 00:30
6.98
3.25
18.9
75.5
0.51
0.00
31.0
0.00
12.8
2,664
2026-11-23 00:25
2.77
0.82
3.27
141
0.52
0.00
32.0
0.00
12.8
4,965
2026-11-23 00:20
7.04
3.23
18.9
65.6
0.53
0.00
32.0
0.00
12.8
2,318
2026-11-23 00:15
3.71
0.81
4.88
29.9
0.53
0.00
30.0
0.00
12.8
1,056
2026-11-23 00:10
3.41
0.82
4.89
59.2
0.49
0.00
33.0
0.00
12.8
2,092
2026-11-23 00:05
4.53
3.25
4.89
31.4
0.49
0.00
31.0
0.00
12.8
1,111
2026-11-23 00:00
3.72
0.83
4.91
30.4
0.49
0.00
31.0
0.00
12.8
1,073
2026-11-22 23:55
7.33
3.23
18.9
28.9
0.47
0.00
0.00
0.00
12.8
1,022
2026-11-22 23:50
3.43
0.83
4.94
52.2
0.46
0.00
32.0
0.00
12.8
1,844
2026-11-22 23:45
3.09
0.86
4.93
57.6
0.47
0.00
30.0
0.00
12.8
2,034
2026-11-22 23:40
1.80
0.84
3.23
69.8
0.46
0.00
32.0
0.00
12.8
2,465
2026-11-22 23:35
3.91
3.20
4.99
80.0
0.48
0.00
31.0
0.00
12.8
2,823
2026-11-22 23:30
3.09
0.89
5.00
82.0
0.48
0.00
28.0
0.00
12.9
2,896
2026-11-22 23:25
3.91
3.17
5.02
80.2
0.46
0.00
27.0
0.00
12.9
2,832
2026-11-22 23:20
4.10
0.94
5.08
0.00
0.46
0.00
31.0
0.00
12.9
0.00
2026-11-22 23:15
3.49
0.97
5.10
52.7
0.47
0.00
33.0
0.00
12.9
1,860
2026-11-22 23:10
4.33
3.13
5.17
51.2
0.46
0.00
31.0
0.00
12.9
1,807
2026-11-22 23:05
4.79
3.12
5.21
25.1
0.45
0.00
30.0
0.00
12.9
886
2026-11-22 23:00
4.82
3.07
5.28
36.7
0.45
0.00
34.0
0.00
12.9
1,297
2026-11-22 22:55
7.10
3.01
18.9
45.5
0.42
0.00
0.00
0.00
12.9
1,608
2026-11-22 22:50
4.86
3.00
5.41
20.2
0.24
0.00
32.0
0.00
12.9
713
2026-11-22 22:45
4.48
2.93
5.51
24.3
0.30
0.00
32.0
0.00
12.9
857
2026-11-22 22:40
3.67
1.34
5.61
35.7
0.26
0.00
31.0
0.00
12.9
1,260
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2022-11-20 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery12.8 V
Last ingest check2 min agopoller runs every 10 minutes