No records inside the last 1 days, so the
charts below are empty. This station holds 6,362 record(s)
in total — try a wider window.
Latest reading
2026-11-21 13:10 station time · 6 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
3,125cusecs
no 3 h reference
Period0 record(s) · 2023-01-28
Water level2.90 mrange 2.89–2.90
Discharge88.5 m³/srange 84.4–93.3
Flow velocity0.37 m/srange 0.35–0.39
Flow directionIncomingraw value 0
Telemetry2 QoSsignal 34.0 dBM
Battery13.6 Vwithin range
Device temperature20.0 °Cinside the gauge enclosure
Sensor tilt51.0 °X 3.00° · Y -6.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-21 13:10
Sensor alignment
Tilt angle51.0 °
X tilt3.00 °
Y tilt-6.00 °
Telemetry & power
Level SNR34.0 dBm
Average SNR14.0 dBm
Quality of service2.00
Device temperature20.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-21 13:10
2.90
2.89
2.90
88.5
0.37
0.00
34.0
2.00
13.6
3,125
2026-11-21 13:05
5.80
1.34
18.9
61.7
0.37
0.00
0.00
0.00
13.6
2,178
2026-11-21 13:00
2.90
2.90
2.91
91.2
0.38
0.00
34.0
0.00
13.6
3,221
2026-11-21 12:55
2.89
2.87
2.90
91.2
0.38
0.00
33.0
0.00
13.6
3,221
2026-11-21 12:50
2.88
2.87
2.89
89.1
0.38
0.00
35.0
0.00
13.6
3,147
2026-11-21 12:45
6.64
2.88
18.9
45.1
0.34
0.00
37.0
0.00
13.6
1,593
2026-11-21 12:40
3.91
2.89
5.60
51.5
0.36
0.00
33.0
0.00
13.6
1,818
2026-11-21 12:35
3.11
1.24
5.59
53.8
0.37
0.00
32.0
0.00
13.6
1,898
2026-11-21 12:30
2.89
2.88
2.90
89.7
0.38
0.00
33.0
0.00
13.6
3,168
2026-11-21 12:25
2.88
2.87
2.90
74.2
0.31
0.00
36.0
0.00
13.6
2,621
2026-11-21 12:20
2.89
2.88
2.90
141
0.63
0.00
36.0
3.00
13.6
4,962
2026-11-21 12:15
3.44
2.90
5.60
72.8
0.39
0.00
32.0
0.00
13.6
2,572
2026-11-21 12:10
2.90
2.89
2.91
89.7
0.37
0.00
34.0
0.00
13.6
3,168
2026-11-21 12:05
6.64
2.87
18.9
34.7
0.36
0.00
35.0
0.00
13.6
1,225
2026-11-21 12:00
2.59
1.34
2.91
156
0.93
0.00
32.0
0.00
13.6
5,509
2026-11-21 11:55
6.34
1.34
18.9
35.3
0.38
0.00
33.0
2.00
13.6
1,245
2026-11-21 11:50
2.59
1.34
2.91
70.1
0.36
0.00
33.0
0.00
13.6
2,476
2026-11-21 11:45
2.90
2.90
2.90
90.9
0.38
0.00
34.0
0.00
13.6
3,210
2026-11-21 11:40
5.79
1.34
18.9
44.0
0.34
0.00
34.0
0.00
13.6
1,553
2026-11-21 11:35
5.80
1.33
18.9
53.5
0.37
0.00
0.00
0.00
13.6
1,889
2026-11-21 11:30
3.11
1.23
5.60
50.0
0.36
0.00
35.0
0.00
13.6
1,767
2026-11-21 11:25
2.91
2.90
2.92
94.4
0.39
0.00
35.0
0.00
13.6
3,334
2026-11-21 11:20
12.5
2.89
18.9
36.2
0.37
0.00
33.0
2.00
13.6
1,280
2026-11-21 11:15
13.6
5.58
18.9
17.2
0.37
0.00
0.00
0.00
13.6
609
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2023-01-28 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery13.6 V
Last ingest check3 min agopoller runs every 10 minutes