No records inside the last 1 days, so the
charts below are empty. This station holds 5,498 record(s)
in total — try a wider window.
Latest reading
2026-11-18 18:10 station time · 13 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
1,681cusecs
no 3 h reference
Period0 record(s) · 2023-10-15
Water level3.62 mrange 1.36–5.49
Discharge47.6 m³/srange 0.00–95.9
Flow velocity0.40 m/srange 0.39–0.40
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 29.0 dBM
Battery13.0 Vwithin range
Device temperature17.0 °Cinside the gauge enclosure
Sensor tilt51.0 °X 3.00° · Y -6.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-18 18:10
Sensor alignment
Tilt angle51.0 °
X tilt3.00 °
Y tilt-6.00 °
Telemetry & power
Level SNR29.0 dBm
Average SNR14.8 dBm
Quality of service0.00
Device temperature17.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-18 18:10
3.62
1.36
5.49
47.6
0.40
0.00
29.0
0.00
13.0
1,681
2026-11-18 18:05
5.80
1.37
18.9
57.3
0.39
0.00
30.0
0.00
13.0
2,023
2026-11-18 18:00
2.89
2.87
2.91
96.3
0.41
0.00
34.0
0.00
13.0
3,401
2026-11-18 17:55
6.12
2.90
18.9
77.0
0.39
0.00
0.00
0.00
13.0
2,718
2026-11-18 17:50
3.13
1.36
5.59
56.4
0.39
0.00
33.0
0.00
13.0
1,991
2026-11-18 17:45
4.17
1.36
5.62
37.9
0.39
0.00
32.0
0.00
13.0
1,337
2026-11-18 17:40
3.44
2.89
5.61
64.7
0.34
0.00
33.0
0.00
13.0
2,283
2026-11-18 17:35
2.88
2.86
2.90
91.7
0.39
0.00
33.0
0.00
13.0
3,238
2026-11-18 17:30
3.93
2.89
5.59
57.3
0.40
0.00
34.0
0.00
13.0
2,022
2026-11-18 17:25
3.44
2.90
5.60
75.7
0.40
0.00
32.0
0.00
13.0
2,674
2026-11-18 17:20
3.95
2.89
5.61
56.5
0.39
0.00
34.0
0.00
13.0
1,994
2026-11-18 17:15
2.89
2.87
2.91
92.4
0.39
0.00
34.0
0.00
13.0
3,263
2026-11-18 17:10
2.90
2.89
2.91
93.3
0.39
0.00
33.0
0.00
13.1
3,295
2026-11-18 17:05
2.88
2.87
2.89
83.3
0.35
0.00
36.0
0.00
13.1
2,942
2026-11-18 17:00
2.90
2.89
2.91
90.4
0.38
0.00
32.0
0.00
13.1
3,192
2026-11-18 16:55
2.56
1.20
2.91
83.4
0.39
0.00
34.0
0.00
13.1
2,945
2026-11-18 16:50
9.32
2.91
18.9
42.3
0.27
0.00
33.0
3.00
13.1
1,493
2026-11-18 16:45
2.88
2.86
2.90
74.1
0.31
0.00
33.0
0.00
13.2
2,618
2026-11-18 16:40
2.87
2.87
2.88
91.6
0.39
1.00
35.0
0.00
13.2
3,235
2026-11-18 16:35
2.89
2.86
2.90
81.7
0.34
0.00
34.0
3.00
13.2
2,885
2026-11-18 16:30
2.87
2.86
2.88
83.6
0.36
1.00
38.0
3.00
13.3
2,952
2026-11-18 16:25
2.88
2.87
2.88
71.6
0.30
1.00
36.0
0.00
13.3
2,529
2026-11-18 16:20
2.90
2.89
2.90
91.4
0.38
0.00
34.0
0.00
13.3
3,228
2026-11-18 16:15
2.89
2.88
2.90
90.8
0.38
0.00
35.0
0.00
13.3
3,207
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2023-10-15 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery13.0 V
Last ingest check33s agopoller runs every 10 minutes