No records inside the last 1 days, so the
charts below are empty. This station holds 5,210 record(s)
in total — try a wider window.
Latest reading
2026-11-18 01:20 station time · 10 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
3,005cusecs
no 3 h reference
Period0 record(s) · 2024-01-31
Water level3.91 mrange 3.17–5.01
Discharge85.1 m³/srange 0.00–149
Flow velocity0.49 m/srange 0.48–0.52
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 31.0 dBM
Battery12.8 Vwithin range
Device temperature11.0 °Cinside the gauge enclosure
Sensor tilt51.0 °X 3.00° · Y -6.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-18 01:20
Sensor alignment
Tilt angle51.0 °
X tilt3.00 °
Y tilt-6.00 °
Telemetry & power
Level SNR31.0 dBm
Average SNR18.6 dBm
Quality of service0.00
Device temperature11.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-18 01:20
3.91
3.17
5.01
85.1
0.49
0.00
31.0
0.00
12.8
3,005
2026-11-18 01:15
4.24
3.20
5.01
57.5
0.51
0.00
31.0
0.00
12.8
2,029
2026-11-18 01:10
7.38
3.20
18.9
29.0
0.49
0.00
0.00
0.00
12.8
1,023
2026-11-18 01:05
3.45
0.91
5.00
58.0
0.51
0.00
30.0
0.00
12.8
2,049
2026-11-18 01:00
3.45
0.90
5.00
56.4
0.49
0.00
29.0
0.00
12.9
1,993
2026-11-18 00:55
3.20
3.19
3.21
144
0.50
0.00
33.0
0.00
12.9
5,089
2026-11-18 00:50
3.72
0.72
4.96
42.9
0.48
0.00
32.0
0.00
12.8
1,514
2026-11-18 00:45
2.18
0.90
4.99
27.8
0.47
0.00
0.00
3.00
12.8
981
2026-11-18 00:40
2.63
0.90
4.96
82.7
0.47
0.00
31.0
2.00
12.8
2,921
2026-11-18 00:35
6.68
3.19
18.9
84.2
0.48
0.00
32.0
0.00
12.8
2,973
2026-11-18 00:30
3.10
0.91
5.00
101
0.44
0.00
31.0
0.00
12.9
3,563
2026-11-18 00:25
3.91
3.18
5.00
8.92
0.24
0.00
32.0
0.00
12.9
315
2026-11-18 00:20
3.90
3.18
5.00
42.5
0.34
0.00
30.0
0.00
12.9
1,501
2026-11-18 00:15
3.05
0.90
4.79
97.4
0.48
0.00
30.0
0.00
12.9
3,440
2026-11-18 00:10
3.46
0.90
5.00
31.8
0.27
0.00
31.0
0.00
12.9
1,122
2026-11-18 00:05
3.55
3.18
5.01
45.5
0.24
0.00
29.0
0.00
12.9
1,605
2026-11-18 00:00
6.34
3.19
18.9
103
0.45
0.00
31.0
0.00
12.9
3,630
2026-11-17 23:55
3.09
0.92
5.01
83.6
0.48
0.00
30.0
0.00
12.9
2,952
2026-11-17 23:50
3.92
3.17
5.01
81.2
0.46
0.00
33.0
0.00
12.9
2,868
2026-11-17 23:45
3.47
0.90
5.02
69.0
0.48
0.00
31.0
0.00
12.8
2,436
2026-11-17 23:40
3.92
3.17
5.04
85.0
0.49
0.00
32.0
0.00
12.8
3,002
2026-11-17 23:35
7.05
3.18
18.9
68.8
0.45
0.00
33.0
0.00
12.8
2,429
2026-11-17 23:30
3.10
0.93
5.04
86.2
0.49
0.00
30.0
0.00
12.9
3,044
2026-11-17 23:25
3.55
3.16
5.05
98.9
0.41
0.00
30.0
0.00
12.9
3,493
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2024-01-31 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery12.8 V
Last ingest check7 min agopoller runs every 10 minutes