No records inside the last 1 days, so the
charts below are empty. This station holds 4,922 record(s)
in total — try a wider window.
Latest reading
2026-11-16 12:40 station time · 19 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
3,185cusecs
no 3 h reference
Period0 record(s) · 2024-09-22
Water level3.48 mrange 3.06–5.13
Discharge90.2 m³/srange 0.00–120
Flow velocity0.42 m/srange 0.41–0.45
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 31.0 dBM
Battery13.4 Vwithin range
Device temperature26.0 °Cinside the gauge enclosure
Sensor tilt50.0 °X 3.00° · Y -7.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-16 12:40
Sensor alignment
Tilt angle50.0 °
X tilt3.00 °
Y tilt-7.00 °
Telemetry & power
Level SNR31.0 dBm
Average SNR19.3 dBm
Quality of service0.00
Device temperature26.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-16 12:40
3.48
3.06
5.13
90.2
0.42
0.00
31.0
0.00
13.4
3,185
2026-11-16 12:35
3.05
3.04
3.06
115
0.43
0.00
34.0
0.00
13.4
4,065
2026-11-16 12:30
2.67
1.11
3.08
87.6
0.41
0.00
34.0
0.00
13.4
3,094
2026-11-16 12:25
3.50
3.05
5.26
87.3
0.41
0.00
32.0
0.00
13.4
3,083
2026-11-16 12:20
3.48
3.05
5.12
86.7
0.40
0.00
33.0
0.00
13.4
3,062
2026-11-16 12:15
3.06
3.05
3.06
109
0.41
0.00
33.0
0.00
13.4
3,846
2026-11-16 12:10
3.05
3.04
3.06
117
0.53
0.00
34.0
2.00
13.4
4,128
2026-11-16 12:05
3.06
3.05
3.07
107
0.40
0.00
29.0
3.00
13.4
3,765
2026-11-16 12:00
3.53
0.96
5.30
41.5
0.41
0.00
30.0
0.00
13.4
1,464
2026-11-16 11:55
3.11
1.12
5.28
63.4
0.40
0.00
32.0
0.00
13.4
2,238
2026-11-16 11:50
4.40
3.05
5.31
43.6
0.41
0.00
32.0
0.00
13.4
1,539
2026-11-16 11:45
5.46
1.13
18.9
65.3
0.41
0.00
33.0
0.00
13.4
2,305
2026-11-16 11:40
3.94
3.01
5.29
23.6
0.43
0.00
33.0
0.00
13.4
834
2026-11-16 11:35
3.50
3.04
5.29
87.5
0.41
0.00
33.0
0.00
13.4
3,090
2026-11-16 11:30
3.04
3.04
3.05
103
0.39
0.00
35.0
0.00
13.4
3,630
2026-11-16 11:25
3.04
3.02
3.05
117
0.45
0.00
33.0
0.00
13.4
4,132
2026-11-16 11:20
3.04
3.03
3.04
109
0.41
0.00
35.0
0.00
13.4
3,835
2026-11-16 11:15
3.12
1.14
5.32
21.6
0.41
0.00
34.0
0.00
13.4
761
2026-11-16 11:10
3.94
3.01
5.31
61.8
0.40
0.00
30.0
0.00
13.4
2,181
2026-11-16 11:05
2.73
1.13
5.30
45.0
0.42
0.00
34.0
0.00
13.4
1,591
2026-11-16 11:00
7.18
1.16
18.9
21.1
0.42
0.00
31.0
0.00
13.4
747
2026-11-16 10:55
3.17
1.02
5.33
42.3
0.40
0.00
32.0
0.00
13.4
1,493
2026-11-16 10:50
3.03
2.99
3.05
85.1
0.41
0.00
32.0
0.00
13.4
3,005
2026-11-16 10:45
3.57
1.16
5.34
55.5
0.42
0.00
33.0
0.00
13.4
1,958
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2024-09-22 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery13.4 V
Last ingest check7 min agopoller runs every 10 minutes