No records inside the last 1 days, so the
charts below are empty. This station holds 4,634 record(s)
in total — try a wider window.
Latest reading
2026-11-16 02:00 station time · 6 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
1,615cusecs
no 3 h reference
Period0 record(s) · 2024-12-04
Water level3.54 mrange 1.12–5.26
Discharge45.7 m³/srange 0.00–117
Flow velocity0.43 m/srange 0.42–0.45
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 33.0 dBM
Battery12.8 Vwithin range
Device temperature13.0 °Cinside the gauge enclosure
Sensor tilt50.0 °X 3.00° · Y -5.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-16 02:00
Sensor alignment
Tilt angle50.0 °
X tilt3.00 °
Y tilt-5.00 °
Telemetry & power
Level SNR33.0 dBm
Average SNR25.7 dBm
Quality of service0.00
Device temperature13.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-16 02:00
3.54
1.12
5.26
45.7
0.43
0.00
33.0
0.00
12.8
1,615
2026-11-16 01:55
3.54
1.09
5.24
55.5
0.42
0.00
31.0
0.00
12.8
1,959
2026-11-16 01:50
2.70
1.07
5.17
57.4
0.44
0.00
30.0
0.00
12.8
2,027
2026-11-16 01:45
3.93
3.08
5.21
69.8
0.43
0.00
31.0
0.00
12.8
2,465
2026-11-16 01:40
3.12
1.04
5.21
36.8
0.45
0.00
33.0
0.00
12.8
1,299
2026-11-16 01:35
2.27
1.03
5.13
74.8
0.45
0.00
33.0
3.00
12.8
2,642
2026-11-16 01:30
3.51
1.01
5.16
85.6
0.45
0.00
32.0
0.00
12.8
3,023
2026-11-16 01:25
3.11
1.00
5.13
77.5
0.46
0.00
29.0
0.00
12.8
2,735
2026-11-16 01:20
3.10
1.00
5.00
94.9
0.48
0.00
32.0
0.00
12.8
3,351
2026-11-16 01:15
3.16
3.15
3.16
132
0.47
0.00
32.0
0.00
12.8
4,651
2026-11-16 01:10
3.16
3.15
3.17
130
0.46
0.00
31.0
0.00
12.8
4,577
2026-11-16 01:05
3.17
3.16
3.18
139
0.49
0.00
30.0
0.00
12.8
4,909
2026-11-16 01:00
3.19
3.18
3.20
143
0.49
0.00
30.0
0.00
12.8
5,036
2026-11-16 00:55
3.20
3.18
3.22
138
0.47
0.00
29.0
0.00
12.8
4,880
2026-11-16 00:50
3.20
3.19
3.21
147
0.51
0.00
30.0
0.00
12.8
5,202
2026-11-16 00:45
3.22
3.21
3.23
149
0.51
0.00
32.0
3.00
12.8
5,269
2026-11-16 00:40
3.22
3.21
3.24
151
0.52
0.00
30.0
0.00
12.8
5,347
2026-11-16 00:35
3.22
3.21
3.23
150
0.51
0.00
31.0
0.00
12.8
5,290
2026-11-16 00:30
2.76
0.83
3.25
118
0.49
0.00
29.0
0.00
12.8
4,174
2026-11-16 00:25
3.24
3.24
3.25
160
0.54
0.00
29.0
0.00
12.8
5,664
2026-11-16 00:20
2.77
0.82
3.27
123
0.51
0.00
31.0
0.00
12.8
4,326
2026-11-16 00:15
3.25
3.24
3.27
152
0.51
0.00
31.0
0.00
12.8
5,371
2026-11-16 00:10
3.26
3.25
3.27
157
0.52
0.00
30.0
0.00
12.8
5,548
2026-11-16 00:05
3.58
3.26
4.86
159
0.53
0.00
31.0
0.00
12.8
5,629
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2024-12-04 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery12.8 V