No records inside the last 1 days, so the
charts below are empty. This station holds 4,634 record(s)
in total — try a wider window.
Latest reading
2026-11-15 22:10 station time · 11 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
5,714cusecs
no 3 h reference
Period0 record(s) · 2024-12-28
Water level3.27 mrange 3.26–3.28
Discharge162 m³/srange 155–172
Flow velocity0.53 m/srange 0.51–0.57
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 33.0 dBM
Battery12.9 Vwithin range
Device temperature14.0 °Cinside the gauge enclosure
Sensor tilt50.0 °X 2.00° · Y -5.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-15 22:10
Sensor alignment
Tilt angle50.0 °
X tilt2.00 °
Y tilt-5.00 °
Telemetry & power
Level SNR33.0 dBm
Average SNR20.2 dBm
Quality of service0.00
Device temperature14.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-15 22:10
3.27
3.26
3.28
162
0.53
0.00
33.0
0.00
12.9
5,714
2026-11-15 22:05
3.27
3.26
3.28
155
0.51
0.00
31.0
0.00
12.9
5,470
2026-11-15 22:00
6.40
3.26
18.9
127
0.53
0.00
31.0
0.00
12.8
4,492
2026-11-15 21:55
6.40
3.25
18.9
118
0.49
0.00
29.0
0.00
12.9
4,157
2026-11-15 21:50
3.26
3.25
3.27
156
0.52
0.00
31.0
0.00
12.9
5,506
2026-11-15 21:45
3.26
3.25
3.28
167
0.55
0.00
29.0
0.00
12.9
5,880
2026-11-15 21:40
2.78
0.79
3.27
135
0.55
0.00
32.0
0.00
12.9
4,757
2026-11-15 21:35
3.26
3.25
3.27
164
0.55
0.00
32.0
0.00
12.9
5,802
2026-11-15 21:30
3.28
3.27
3.29
163
0.54
0.00
31.0
0.00
12.8
5,767
2026-11-15 21:25
3.27
3.26
3.28
163
0.54
0.00
30.0
0.00
12.9
5,767
2026-11-15 21:20
3.27
3.26
3.28
157
0.51
0.00
31.0
0.00
12.9
5,544
2026-11-15 21:15
3.27
3.26
3.28
160
0.53
0.00
32.0
0.00
12.9
5,661
2026-11-15 21:10
3.27
3.26
3.28
160
0.53
0.00
29.0
0.00
12.9
5,643
2026-11-15 21:05
3.27
3.26
3.28
167
0.55
0.00
28.0
0.00
12.9
5,898
2026-11-15 21:00
3.27
3.26
3.29
156
0.51
0.00
32.0
0.00
12.9
5,509
2026-11-15 20:55
2.75
0.68
3.28
127
0.52
0.00
30.0
0.00
12.9
4,499
2026-11-15 20:50
3.28
3.27
3.28
159
0.53
0.00
29.0
0.00
12.9
5,622
2026-11-15 20:45
3.28
3.26
3.29
163
0.54
0.00
31.0
0.00
12.9
5,742
2026-11-15 20:40
6.40
3.24
18.9
127
0.53
0.00
30.0
0.00
12.9
4,488
2026-11-15 20:35
2.79
0.79
3.29
143
0.52
0.00
31.0
0.00
12.9
5,064
2026-11-15 20:30
3.27
3.24
3.28
142
0.52
0.00
29.0
0.00
12.9
5,004
2026-11-15 20:25
3.27
3.27
3.28
165
0.55
0.00
28.0
0.00
12.9
5,830
2026-11-15 20:20
3.27
3.25
3.28
155
0.51
0.00
29.0
0.00
12.9
5,477
2026-11-15 20:15
3.27
3.27
3.28
161
0.53
0.00
31.0
0.00
12.9
5,696
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2024-12-28 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery12.9 V
Last ingest check9 min agopoller runs every 10 minutes