No records inside the last 1 days, so the
charts below are empty. This station holds 4,346 record(s)
in total — try a wider window.
Latest reading
2026-11-15 03:50 station time · 8 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
3,793cusecs
no 3 h reference
Period0 record(s) · 2025-04-26
Water level6.35 mrange 3.19–18.9
Discharge107 m³/srange 0.00–139
Flow velocity0.47 m/srange 0.45–0.48
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 30.0 dBM
Battery12.8 Vwithin range
Device temperature16.0 °Cinside the gauge enclosure
Sensor tilt50.0 °X 5.00° · Y -6.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-15 03:50
Sensor alignment
Tilt angle50.0 °
X tilt5.00 °
Y tilt-6.00 °
Telemetry & power
Level SNR30.0 dBm
Average SNR19.3 dBm
Quality of service0.00
Device temperature16.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-15 03:50
6.35
3.19
18.9
107
0.47
0.00
30.0
0.00
12.8
3,793
2026-11-15 03:45
3.21
3.20
3.23
134
0.46
0.00
29.0
0.00
12.8
4,718
2026-11-15 03:40
3.21
3.21
3.22
142
0.49
0.00
30.0
0.00
12.8
5,029
2026-11-15 03:35
3.22
3.20
3.22
145
0.49
0.00
31.0
0.00
12.8
5,121
2026-11-15 03:30
3.22
3.21
3.23
146
0.49
0.00
31.0
0.00
12.7
5,145
2026-11-15 03:25
3.23
3.21
3.24
135
0.46
0.00
30.0
0.00
12.7
4,757
2026-11-15 03:20
3.22
3.21
3.23
142
0.48
0.00
30.0
0.00
12.8
5,015
2026-11-15 03:15
3.22
3.21
3.23
126
0.48
0.00
30.0
0.00
12.8
4,460
2026-11-15 03:10
3.22
3.21
3.23
137
0.47
0.00
31.0
0.00
12.8
4,824
2026-11-15 03:05
3.23
3.22
3.24
140
0.48
0.00
30.0
0.00
12.8
4,955
2026-11-15 03:00
3.22
3.22
3.23
143
0.49
0.00
30.0
0.00
12.8
5,057
2026-11-15 02:55
3.23
3.21
3.24
144
0.49
0.00
29.0
0.00
12.8
5,078
2026-11-15 02:50
3.22
3.21
3.24
141
0.48
0.00
29.0
0.00
12.8
4,969
2026-11-15 02:45
3.23
3.21
3.24
141
0.48
0.00
32.0
0.00
12.8
4,983
2026-11-15 02:40
3.23
3.22
3.24
145
0.49
0.00
29.0
0.00
12.8
5,114
2026-11-15 02:35
5.89
0.84
18.9
87.3
0.50
0.00
31.0
0.00
12.8
3,083
2026-11-15 02:30
3.23
3.22
3.24
152
0.51
0.00
31.0
0.00
12.8
5,368
2026-11-15 02:25
3.23
3.22
3.24
150
0.51
0.00
30.0
0.00
12.8
5,304
2026-11-15 02:20
3.23
3.22
3.25
141
0.48
0.00
31.0
0.00
12.8
4,990
2026-11-15 02:15
3.23
3.21
3.24
143
0.48
0.00
31.0
0.00
12.8
5,046
2026-11-15 02:10
3.23
3.22
3.23
137
0.47
0.00
31.0
0.00
12.8
4,852
2026-11-15 02:05
3.23
3.22
3.25
146
0.49
0.00
31.0
0.00
12.8
5,145
2026-11-15 02:00
3.23
3.21
3.24
140
0.47
0.00
32.0
0.00
12.8
4,944
2026-11-15 01:55
3.23
3.21
3.24
132
0.46
0.00
31.0
0.00
12.8
4,665
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2025-04-26 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery12.8 V
Last ingest check6 min agopoller runs every 10 minutes