No records inside the last 1 days, so the
charts below are empty. This station holds 4,058 record(s)
in total — try a wider window.
Latest reading
2026-11-13 10:50 station time · 12 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
2,755cusecs
no 3 h reference
Period0 record(s) · 2025-12-13
Water level2.95 mrange 2.95–2.96
Discharge78.0 m³/srange 0.00–99.8
Flow velocity0.40 m/srange 0.39–0.41
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 34.0 dBM
Battery13.4 Vwithin range
Device temperature21.0 °Cinside the gauge enclosure
Sensor tilt50.0 °X 3.00° · Y -5.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-13 10:50
Sensor alignment
Tilt angle50.0 °
X tilt3.00 °
Y tilt-5.00 °
Telemetry & power
Level SNR34.0 dBm
Average SNR17.1 dBm
Quality of service0.00
Device temperature21.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-13 10:50
2.95
2.95
2.96
78.0
0.40
0.00
34.0
0.00
13.4
2,755
2026-11-13 10:45
3.12
1.27
5.52
39.8
0.40
0.00
33.0
0.00
13.4
1,405
2026-11-13 10:40
3.10
1.12
5.50
60.6
0.41
0.00
32.0
0.00
13.4
2,139
2026-11-13 10:35
4.10
1.10
5.49
40.3
0.40
0.00
32.0
0.00
13.4
1,422
2026-11-13 10:30
2.79
1.28
5.51
48.6
0.39
0.00
32.0
0.00
13.4
1,716
2026-11-13 10:25
3.12
1.27
5.50
59.9
0.41
0.00
33.0
0.00
13.4
2,115
2026-11-13 10:20
3.34
1.28
5.51
18.8
0.40
0.00
34.0
0.00
13.4
664
2026-11-13 10:15
5.14
1.27
18.9
38.8
0.40
0.00
33.0
0.00
13.4
1,370
2026-11-13 10:10
2.62
1.29
2.96
98.2
0.40
0.00
32.0
0.00
13.5
3,468
2026-11-13 10:05
7.64
2.92
18.9
20.7
0.40
0.00
31.0
0.00
13.5
730
2026-11-13 10:00
2.95
2.94
2.95
76.0
0.38
0.00
33.0
0.00
13.5
2,683
2026-11-13 09:55
3.63
1.28
5.51
38.6
0.40
0.00
33.0
0.00
13.5
1,363
2026-11-13 09:50
2.61
1.27
2.96
77.0
0.39
0.00
30.0
0.00
13.6
2,719
2026-11-13 09:45
2.61
1.28
2.96
78.3
0.40
0.00
34.0
0.00
13.5
2,765
2026-11-13 09:40
3.97
2.94
5.50
54.6
0.38
0.00
32.0
1.00
13.5
1,927
2026-11-13 09:35
3.13
1.27
5.52
61.2
0.40
0.00
33.0
1.00
13.3
2,161
2026-11-13 09:30
2.28
1.27
2.96
67.5
0.39
0.00
34.0
0.00
13.3
2,385
2026-11-13 09:25
3.64
1.28
5.53
63.9
0.37
0.00
32.0
0.00
13.3
2,256
2026-11-13 09:20
6.66
2.94
18.9
56.3
0.39
0.00
0.00
0.00
13.1
1,988
2026-11-13 09:15
3.46
2.94
5.50
78.1
0.40
0.00
34.0
0.00
13.0
2,759
2026-11-13 09:10
2.95
2.93
2.96
103
0.42
0.00
35.0
0.00
13.0
3,644
2026-11-13 09:05
3.44
2.94
5.39
66.4
0.38
0.00
31.0
0.00
13.0
2,343
2026-11-13 09:00
2.27
1.24
2.96
57.5
0.39
0.00
33.0
0.00
12.9
2,030
2026-11-13 08:55
3.12
1.27
5.51
39.9
0.32
0.00
32.0
0.00
12.9
1,410
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2025-12-13 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery13.4 V
Last ingest check9 min agopoller runs every 10 minutes