No records inside the last 1 days, so the
charts below are empty. This station holds 3,770 record(s)
in total — try a wider window.
Latest reading
2026-11-12 13:00 station time · 4 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
4,665cusecs
no 3 h reference
Period0 record(s) · 2026-04-09
Water level2.85 mrange 2.84–2.85
Discharge132 m³/srange 129–135
Flow velocity0.57 m/srange 0.55–0.58
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 32.0 dBM
Battery13.0 Vwithin range
Device temperature21.0 °Cinside the gauge enclosure
Sensor tilt50.0 °X 3.00° · Y -6.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-12 13:00
Sensor alignment
Tilt angle50.0 °
X tilt3.00 °
Y tilt-6.00 °
Telemetry & power
Level SNR32.0 dBm
Average SNR24.3 dBm
Quality of service0.00
Device temperature21.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-12 13:00
2.85
2.84
2.85
132
0.57
0.00
32.0
0.00
13.0
4,665
2026-11-12 12:55
2.58
1.40
2.88
136
0.58
0.00
34.0
0.00
13.0
4,785
2026-11-12 12:50
2.85
2.85
2.87
136
0.59
0.00
33.0
0.00
13.0
4,803
2026-11-12 12:45
2.87
2.86
2.87
138
0.59
0.00
33.0
0.00
13.1
4,866
2026-11-12 12:40
2.86
2.85
2.87
415
1.78
0.00
34.0
0.00
13.0
14,656
2026-11-12 12:35
3.43
2.86
5.61
105
0.56
0.00
33.0
0.00
13.0
3,690
2026-11-12 12:30
2.59
1.36
2.91
56.1
0.39
0.00
33.0
0.00
12.9
1,980
2026-11-12 12:25
2.90
2.89
2.90
357
1.54
0.00
33.0
0.00
12.9
12,607
2026-11-12 12:20
4.52
2.90
5.61
41.3
0.42
0.00
31.0
0.00
12.9
1,460
2026-11-12 12:15
3.97
2.90
5.59
42.6
0.34
0.00
31.0
0.00
12.9
1,506
2026-11-12 12:10
4.18
1.34
5.58
28.3
0.37
0.00
33.0
0.00
12.9
999
2026-11-12 12:05
3.44
2.90
5.54
89.1
0.37
0.00
34.0
0.00
12.9
3,147
2026-11-12 12:00
3.44
2.88
5.58
74.7
0.39
0.00
35.0
0.00
12.9
2,637
2026-11-12 11:55
3.45
2.92
5.57
73.2
0.38
0.00
33.0
0.00
13.0
2,586
2026-11-12 11:50
2.91
2.90
2.92
103
0.42
0.00
35.0
0.00
13.0
3,641
2026-11-12 11:45
2.91
2.90
2.92
77.9
0.32
0.00
37.0
0.00
13.0
2,751
2026-11-12 11:40
2.92
2.90
2.92
78.6
0.32
0.00
35.0
0.00
13.1
2,776
2026-11-12 11:35
2.91
2.90
2.92
98.1
0.41
0.00
38.0
0.00
13.1
3,464
2026-11-12 11:30
2.93
2.92
2.94
97.6
0.40
0.00
37.0
0.00
13.1
3,447
2026-11-12 11:25
2.94
2.94
2.95
95.2
0.39
0.00
33.0
0.00
13.2
3,362
2026-11-12 11:20
3.13
1.27
5.53
59.9
0.41
0.00
31.0
3.00
13.1
2,116
2026-11-12 11:15
2.62
1.27
2.96
82.4
0.41
0.00
30.0
0.00
13.1
2,910
2026-11-12 11:10
3.47
2.96
5.51
83.0
0.42
0.00
31.0
0.00
13.1
2,931
2026-11-12 11:05
2.62
1.26
2.97
78.9
0.40
0.00
33.0
0.00
13.2
2,785
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2026-04-09 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery13.0 V
Last ingest check86s agopoller runs every 10 minutes