No records inside the last 1 days, so the
charts below are empty. This station holds 3,770 record(s)
in total — try a wider window.
Latest reading
2026-11-12 10:20 station time · 5 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
2,471cusecs
no 3 h reference
Period0 record(s) · 2026-04-24
Water level3.46 mrange 2.94–5.48
Discharge70.0 m³/srange 0.00–106
Flow velocity0.40 m/srange 0.38–0.42
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 31.0 dBM
Battery13.1 Vwithin range
Device temperature20.0 °Cinside the gauge enclosure
Sensor tilt50.0 °X 3.00° · Y -6.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-12 10:20
Sensor alignment
Tilt angle50.0 °
X tilt3.00 °
Y tilt-6.00 °
Telemetry & power
Level SNR31.0 dBm
Average SNR16.7 dBm
Quality of service0.00
Device temperature20.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-12 10:20
3.46
2.94
5.48
70.0
0.40
0.00
31.0
0.00
13.1
2,471
2026-11-12 10:15
3.46
2.95
5.50
77.8
0.39
0.00
33.0
0.00
13.1
2,746
2026-11-12 10:10
2.97
2.96
2.98
102
0.41
0.00
34.0
3.00
13.1
3,609
2026-11-12 10:05
2.96
2.95
2.97
83.0
0.41
0.00
32.0
0.00
13.1
2,931
2026-11-12 10:00
3.46
2.96
5.47
80.7
0.41
0.00
33.0
0.00
13.2
2,850
2026-11-12 09:55
2.96
2.94
2.97
102
0.41
0.00
35.0
0.00
13.2
3,609
2026-11-12 09:50
2.95
2.94
2.96
101
0.41
0.00
33.0
0.00
13.2
3,581
2026-11-12 09:45
3.46
2.96
5.47
79.9
0.39
0.00
32.0
0.00
13.1
2,822
2026-11-12 09:40
3.97
2.95
5.48
71.0
0.40
0.00
33.0
0.00
13.1
2,506
2026-11-12 09:35
3.93
2.96
5.48
58.2
0.40
0.00
34.0
0.00
13.1
2,056
2026-11-12 09:30
3.52
1.09
5.46
40.6
0.40
0.00
32.0
0.00
12.9
1,434
2026-11-12 09:25
3.90
2.96
5.48
62.1
0.41
0.00
33.0
0.00
12.9
2,192
2026-11-12 09:20
7.16
2.94
18.9
37.8
0.39
0.00
33.0
0.00
12.8
1,336
2026-11-12 09:15
6.16
2.96
18.9
79.5
0.40
0.00
0.00
0.00
12.9
2,807
2026-11-12 09:10
4.10
1.33
5.48
19.3
0.39
0.00
33.0
1.00
12.9
683
2026-11-12 09:05
4.40
2.94
5.48
39.4
0.40
0.00
32.0
0.00
12.9
1,391
2026-11-12 09:00
3.47
2.96
5.48
81.3
0.41
0.00
32.0
0.00
12.8
2,871
2026-11-12 08:55
3.96
2.96
5.48
59.9
0.40
0.00
30.0
0.00
12.9
2,114
2026-11-12 08:50
7.17
2.96
18.9
39.4
0.39
0.00
0.00
0.00
12.9
1,391
2026-11-12 08:45
3.63
1.25
5.49
40.4
0.40
0.00
33.0
0.00
12.9
1,426
2026-11-12 08:40
3.13
1.26
5.47
61.6
0.41
0.00
34.0
0.00
12.8
2,174
2026-11-12 08:35
2.63
1.25
2.98
81.0
0.40
0.00
34.0
0.00
12.8
2,860
2026-11-12 08:30
2.62
1.25
2.97
83.8
0.42
0.00
32.0
3.00
12.8
2,959
2026-11-12 08:25
3.96
2.96
5.48
59.8
0.40
0.00
33.0
0.00
12.8
2,112
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2026-04-24 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery13.1 V
Last ingest check2 min agopoller runs every 10 minutes