No records inside the last 1 days, so the
charts below are empty. This station holds 3,770 record(s)
in total — try a wider window.
Latest reading
2026-11-12 08:30 station time · 4 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
2,959cusecs
no 3 h reference
Period0 record(s) · 2026-05-07
Water level2.62 mrange 1.25–2.97
Discharge83.8 m³/srange 0.00–111
Flow velocity0.42 m/srange 0.38–0.45
Flow directionIncomingraw value 0
Telemetry3 QoSsignal 32.0 dBM
Battery12.8 Vwithin range
Device temperature18.0 °Cinside the gauge enclosure
Sensor tilt50.0 °X 2.00° · Y -6.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-12 08:30
Sensor alignment
Tilt angle50.0 °
X tilt2.00 °
Y tilt-6.00 °
Telemetry & power
Level SNR32.0 dBm
Average SNR9.67 dBm
Quality of service3.00
Device temperature18.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-12 08:30
2.62
1.25
2.97
83.8
0.42
0.00
32.0
3.00
12.8
2,959
2026-11-12 08:25
3.96
2.96
5.48
59.8
0.40
0.00
33.0
0.00
12.8
2,112
2026-11-12 08:20
2.63
1.26
2.97
61.8
0.41
0.00
33.0
0.00
12.9
2,181
2026-11-12 08:15
6.81
1.24
18.9
30.2
0.41
0.00
34.0
0.00
12.8
1,068
2026-11-12 08:10
6.15
2.95
18.9
79.6
0.40
0.00
0.00
0.00
12.8
2,811
2026-11-12 08:05
6.16
2.96
18.9
82.6
0.41
0.00
32.0
0.00
12.8
2,917
2026-11-12 08:00
2.28
1.25
2.96
61.6
0.41
0.00
30.0
0.00
12.8
2,175
2026-11-12 07:55
6.79
1.09
18.9
19.9
0.40
0.00
33.0
0.00
12.8
701
2026-11-12 07:50
4.04
2.95
5.82
71.0
0.41
0.00
30.0
0.00
12.8
2,507
2026-11-12 07:45
6.33
1.26
18.9
40.9
0.42
0.00
34.0
0.00
12.8
1,443
2026-11-12 07:40
2.62
1.26
2.97
80.9
0.40
0.00
33.0
0.00
12.8
2,857
2026-11-12 07:35
13.1
2.97
18.9
19.6
0.41
0.00
33.0
0.00
12.8
694
2026-11-12 07:30
2.78
1.25
5.48
41.4
0.41
0.00
32.0
0.00
12.8
1,461
2026-11-12 07:25
6.16
2.96
18.9
84.5
0.42
0.00
0.00
0.00
12.8
2,984
2026-11-12 07:20
3.96
2.96
5.49
70.4
0.40
0.00
27.0
0.00
12.8
2,486
2026-11-12 07:15
2.97
2.96
2.97
99.7
0.40
0.00
33.0
0.00
12.8
3,521
2026-11-12 07:10
3.96
2.95
5.47
58.6
0.40
0.00
32.0
0.00
12.8
2,068
2026-11-12 07:05
12.5
2.93
18.9
40.5
0.38
0.00
0.00
0.00
12.8
1,428
2026-11-12 07:00
3.18
1.51
5.47
70.1
0.40
0.00
35.0
0.00
12.8
2,476
2026-11-12 06:55
3.13
1.26
5.48
59.2
0.40
0.00
31.0
0.00
12.8
2,091
2026-11-12 06:50
5.78
1.09
18.9
56.6
0.39
0.00
32.0
0.00
12.8
2,001
2026-11-12 06:45
9.35
2.96
18.9
57.9
0.38
0.00
33.0
0.00
12.8
2,044
2026-11-12 06:40
2.60
1.14
2.97
75.2
0.38
0.00
33.0
0.00
12.8
2,656
2026-11-12 06:35
3.97
2.96
5.47
58.9
0.40
0.00
33.0
0.00
12.8
2,080
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2026-05-07 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery12.8 V
Last ingest check2 min agopoller runs every 10 minutes