No records inside the last 1 days, so the
charts below are empty. This station holds 3,482 record(s)
in total — try a wider window.
Latest reading
2026-11-12 00:50 station time · 7 min ago
· daily figures cover the calendar midnight–midnight day
Discharge
2,196cusecs
no 3 h reference
Period0 record(s) · 2026-06-24
Water level9.34 mrange 2.94–18.9
Discharge62.2 m³/srange 0.00–107
Flow velocity0.41 m/srange 0.39–0.43
Flow directionIncomingraw value 0
Telemetry0 QoSsignal 32.0 dBM
Battery12.8 Vwithin range
Device temperature18.0 °Cinside the gauge enclosure
Sensor tilt50.0 °X 3.00° · Y -5.00°
Water level
every reading · m · WaterLevel_Avg
No readings in this window.
Discharge
every reading · cusecs · Discharge_Avg
No readings in this window.
Flow velocity
every reading · m/s · Velocity_Avg
No readings in this window.
Telemetry signal
signal-to-noise at the gauge · dBM · LevelSNR
No readings in this window.
Battery
lowest reading per bucket · Volts · BattV_Min
No readings in this window.
Gauge condition
latest reading · 2026-11-12 00:50
Sensor alignment
Tilt angle50.0 °
X tilt3.00 °
Y tilt-5.00 °
Telemetry & power
Level SNR32.0 dBm
Average SNR20.9 dBm
Quality of service0.00
Device temperature18.0 °
Alignment and link quality decide whether a level reading can be
trusted. A gauge knocked askew by debris or a flood keeps reporting numbers — they
are simply wrong — so these belong beside the readings, not buried below them.
Recent readings
last 24 record(s) · headline
variables · every stored variable is in the parameter list below
Time
WaterLevel_Avg m
WaterLevel_Min m
WaterLevel_Max m
Discharge_Avg —
Velocity_Avg m/s
FlowDirection —
LevelSNR dBM
QoS —
BattV_Min Volts
Discharge_Avg cusecs
2026-11-12 00:50
9.34
2.94
18.9
62.2
0.41
0.00
32.0
0.00
12.8
2,196
2026-11-12 00:45
3.41
2.94
5.31
111
0.74
0.00
33.0
0.00
12.8
3,906
2026-11-12 00:40
2.93
2.93
2.94
150
0.61
0.00
34.0
0.00
12.8
5,301
2026-11-12 00:35
2.92
2.92
2.93
144
0.59
0.00
31.0
0.00
12.9
5,085
2026-11-12 00:30
2.62
1.26
2.96
127
0.59
0.00
33.0
0.00
12.8
4,474
2026-11-12 00:25
2.94
2.92
2.96
349
1.44
1.00
32.0
0.00
12.8
12,318
2026-11-12 00:20
2.93
2.92
2.94
147
0.60
0.00
31.0
0.00
12.8
5,177
2026-11-12 00:15
2.95
2.94
2.96
117
0.47
0.00
33.0
0.00
12.9
4,125
2026-11-12 00:10
3.46
2.94
5.50
78.2
0.39
0.00
33.0
0.00
12.9
2,761
2026-11-12 00:05
3.46
2.93
5.50
78.5
0.40
0.00
32.0
0.00
12.9
2,771
2026-11-12 00:00
2.95
2.94
2.96
89.2
0.36
0.00
32.0
0.00
12.8
3,150
2026-11-11 23:55
2.94
2.93
2.95
81.2
0.33
0.00
33.0
0.00
12.8
2,868
2026-11-11 23:50
2.95
2.94
2.96
95.3
0.38
0.00
32.0
0.00
12.9
3,365
2026-11-11 23:45
2.94
2.94
2.95
94.9
0.38
0.00
32.0
3.00
12.9
3,351
2026-11-11 23:40
2.94
2.94
2.95
94.6
0.38
0.00
33.0
0.00
12.8
3,341
2026-11-11 23:35
2.94
2.92
2.95
102
0.41
0.00
33.0
0.00
12.8
3,599
2026-11-11 23:30
2.61
1.30
2.95
95.6
0.39
0.00
32.0
0.00
12.9
3,376
2026-11-11 23:25
3.61
1.29
5.52
39.3
0.39
0.00
34.0
1.00
12.9
1,388
2026-11-11 23:20
2.94
2.92
2.95
93.6
0.38
0.00
33.0
0.00
12.9
3,305
2026-11-11 23:15
3.61
1.30
5.54
38.3
0.39
0.00
34.0
0.00
12.8
1,354
2026-11-11 23:10
2.60
1.30
2.93
54.5
0.38
0.00
32.0
0.00
12.9
1,926
2026-11-11 23:05
3.45
2.91
5.55
57.0
0.40
0.00
33.0
0.00
12.9
2,012
2026-11-11 23:00
3.13
1.32
5.57
124
0.67
0.00
33.0
0.00
12.9
4,379
2026-11-11 22:55
2.91
2.90
2.92
360
1.49
1.00
36.0
3.00
12.9
12,720
All parameters
0 reporting variables across
0 instrument group(s) · statistics over 2026-06-24 · click to expand
Discharge is shown twice, in m³/s and in
cusecs (ft³/s, the unit Pakistani canal and barrage figures use).
Cusecs is the stored reading × 35.3147 — a display conversion only; the store
and /api/* return exactly what the gauge recorded.
Note that these loggers declare no unit for their discharge columns, so m³/s
is inferred from it being the hydrological default rather than read from the header.
Data health
whether the instrument and the poller are keeping up
Completeness—interval unknown
Outages in window0none detected
Battery12.8 V
Last ingest check4 min agopoller runs every 10 minutes